Vivotek DVR ND8301 Manual de usuario Pagina 208

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 212
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 207
VIVOTEK
208 - User's Manual
Appendix A Rebuilding a RAID Volume
If a drive fails, the failure will be indicated by the system fault LED or the Disk Status panel. If a disk drive
fails in a RAID1 volume, rst locate the faulty drive in the Disk Status panel, remove the faulty drive with
a drive of the same capacity and rotation speed.
Note that you must carefully identify the faulty drive. Replacing the wrong drive from a RAID1
volume will result in losing 2 member drives. If a RAID1 volume loses 2 members, all data will be
lost on that volume.
You should be prompted by the message if a hard drive fails or was
removed. An incorrect or abrupt shutdown of the system may also
force the system to rebuild a RAID volume. Data may not have all been
properly distributed to hard drives when inappropirately shut down.